ACTentryA10VR-SK
ACTentryA10VR-FK
ACTentry A10 Operating and Installation Instructions
2
Installation Notes
• Remember to Factory Default the ACTentry A10 before programming
• Remember to place the supplied varistor across the terminals of the door strike coil to protect the relay
contacts
• Never use the on-board relay to switch AC mains voltage. An external relay, electrically isolated from
the ACTentry A10 should be used for this purpose.
• Remember to change the programming code.
Important
As with any Access Control system, always ensure there is an alternate means of escape in the event of
the unit failing to operate due to power loss or in the event o re.
Product Specication
Number of Users 10 PIN codes
Supply Voltage 12 V AC or DC
Current Consumption 30mA (nominal), 100mA (maximum)
Operating Temperature -10 to +50 degrees C
Door Open Time 0 - 4 minutes
Relay Contact Rating 5A / 50Vac
Controller Size Flush Mount 378 x 144x11mm
Surface Mount: 358 x 125 x 38mm
Water Resistance Medium IP54
Ordering Information
Vandal Resistant Door Entry Panel with integrated ACT 10 Digital Keypad, Call Button
and Speech Unit in a Surface Mount Kit, Door Intercom Handset & Power Supply
Vandal Resistant Door Entry Panel with integrated ACT 10 Digital Keypad, Call Button
and Speech Unit in a Flush Mount Kit, Door Intercom Handset and Power Supply
Vandal Resistant Door Entry Panel with integrated ACT 10 Digital Keypad, Call Button
and Speech Unit for Surface Mounting
ACTentryA10VR-S
ACTentryA10VR-F
Vandal Resistant Door Entry Panel with integrated ACT 10 Digital Keypad, Call Button
and Speech Unit for Flush Mounting
ACTentry A10
Intercom Handset
ACTentry Door Intercom Handset for use with the ACTentry A10. Internal use only.
This is a 1 Amp Power Supply Unit
ACTentry 1A PSU
Commentaires sur ces manuels