When Performance Counts
47
From To Network Type Cable Type* Comments
ACTpro Controller ACTpro Door stations (ACTpro 100 /
ACTpro 200)
RS485 Screen twisted pair(STP) equivalent to
Belden 9501 or shielded Cat5.
Max distance 1.4 km
14 additional doors
ACTpro Controllers / Door Stations ACTpro-X readers ACT protocol 8 core Screen Max distance 100m if powered from 12V
source
ACTpro 3000 Door Controller
expanded up to 16 doors with
ACTpro 100 and 200 Door Stations
Cabling Chart
* Note: If using UTP (Unshielded Twisted Pair) such as Cat 5 please ensure that the cable is not located near sources of electrical noise.