When Performance CountsiIntroductionACT supplies Access Control and Door Entry products to the market. This catalogue has been put together to provide
When Performance Counts 4Proximity Cards & Fobs (125 kHz) FeaturesACT ISO proximity cardsuitable for printingmax range of up to 8cmsuppl
When Performance Counts5Cards & Fobs AccessoriesFeaturesplastic holder for cardsattach to lanyard or clipProduct Code ACT CardholderCardhol
When Performance Counts 6ACT 10(Pin only)ACT 5 (Pin only)ACT 5prox (Pin & Prox)Operating Voltage12 - 24 Volts AC / DC 12 - 24 Volts AC / DC 12 - 2
When Performance Counts7ACT 5 / 5proxProduct Schematics cont’dInstallation NotesACT 5 / ACT 5prox The ACT 5 / 5prox require operating voltage of 12 -
When Performance Counts 8ACT 10(Pin only)ACT 5(Pin only)ACT 5prox(Pin & Prox)Doors2 1 1Users10 10 50User Groups1Pin OnlyPin & CardPin or CardC
When Performance Counts9Featuresproximity reader / controller1,000 users standalone / master slave / networkable programmable inputs/outputs:
When Performance Counts10Product Code ACTsmart2 1090(includes keypad, flush mount plate, surface mount collar, 1 varistor & manual)Featurespin re
When Performance Counts11Reader / Controller Accessories Featuresenhances security of ACTsmart2 installations by locating the relay inside t
When Performance Counts12Reader / Controller Cards & Fobs (125 kHz) FeaturesACT ISO proximity cardsuitable for printingmax range of up to 8
When Performance Counts13Radio ReceiverFeatures integrates with ACTsmart2 and ACTpro-X readers integrates with 3rd party systems range of up to
When Performance CountsiiIndexProduct Name Description PageStandalone Digital KeypadsACT 10pin only digital keypad, 10 user codes, 2 user groups, indo
When Performance Counts14Cards & Fobs AccessoriesCard Printing Bureau ServicesCard IDFeatures personalised printing e.g. employee name, photo,
When Performance Counts15Network Controller Software Featuresrequired for ACTsmart2 software can control up to 8 ACTsmart2 devices1000 users1
When Performance Counts16 ACTsmart2 1070 / 1080 / 1090 Reader / ControllerOperating Voltage 12 - 24 Volt AC or DCCurrent Consumption 60 / 100 mA
When Performance Counts17ACTsmart2 Standalone Reader / ControllerACTsmart2 1080 Master Slave ConfigurationFrom To Network Type Cable Type* CommentsMast
When Performance Counts18From To Network Type Cable Type* CommentsPC ACTsmart controller RS232 Screen twisted pair (STP)Max distance 20m approxACTsma
When Performance Counts19From To Network Type Cable Type CommentsACTsmart controller ACTpro-X reader ACT protocol 8 core Screen Max distance 100mFrom
When Performance Counts20ACTsmart2 with ACT 433RX Long Range Reader
When Performance Counts21Installation NotesReadersControllerSmart LockACTsmart2 1070 (RFID Prox only)ACTsmart2 1080 (Pin and RFID prox)ACTsmart2 1090
When Performance Counts22ACTsmart2 1070(Prox only)ACTsmart2 1080(Pin & Prox)ACTsmart2 1090(Pin only)Doors1 1 1Users1000 1000 (500 Pin & Card)
When Performance Counts23Features multi-format slimline proximity mullion readerACTProx cards and fobs supportedHID cards and fobs supported
When Performance CountsiiiIndexProduct Name Description PageReader / Controller (125 kHz)ACTsmart2 1070 (Proximity only)ACT RFID proximity reader / co
When Performance Counts24Features multi-format proximity only readerACTProx cards and fobs supported HID cards and fobs supported “Clock &
When Performance Counts25Proximity Cards & Fobs (125 kHz) FeaturesACT ISO proximity cardsuitable for printingmax range of up to 8cmsuppl
When Performance Counts26FeaturesHID RFID proximity key boxmax range of up to 6 cmsupplied in pack of 10 (batch) Product Code HIDProx Fob-B
When Performance Counts27Proximity Reader AccessoriesFeaturesflush plate for the ACTpro-X 1030OMstainless steel / brassfits standard single gang e
When Performance Counts28Features Pin only readerPotted electronics“Clock & Data” or “Wiegand” outputTri colour LED indicationsbleep t
When Performance Counts29Features track 2 magnetic swipe reader“Clock & Data” outputBi colour LED indications2 meter pigtail lead vand
When Performance Counts30Features proximity only mifare reader configurable as “Serial”, “Reverse Serial” or “Sector” readerdefault to read from
When Performance Counts31HID iClass R10 Reader HID iClass R40 ReaderHID iClass RP40 ReaderFeatures proximity contactless smartcard reader“Clock &am
When Performance Counts32Featuresfor use with ACTpro mifare 1040 / 1050proximity mifare IKB fobmax range of 3cmnot suitable for printingsu
When Performance Counts33Radio ReceiverFeaturesintegrates with ACTpro-X and ACTsmart2 readers integrates with 3rd party systemsrange of up to
When Performance CountsivIndexProduct Name Description PageProximity Readers, Accessories and Cards and Fobs (125 kHz) ACTpro-X 1030 (Proximity only)
When Performance Counts34Features Identification or Verification modes 500 fingerprint templates (identification mode) or 4000 fingerprint templates
When Performance Counts35Featuresstandalone / networkedover 500 user templates integrated keypadcard reader input fast enrolment & del
When Performance Counts36Card Printing Bureau ServicesCard IDFeatures personalised printing e.g. employee name, photo, department, etcProduct Code
When Performance Counts37ACTpro3000 (2 Door Controller)Door ControllersACTpro 3000 Memory CardFeatures 2 door controller expandable to 16 doors usi
When Performance Counts38Door Controllers (contd.)Featuressingle door controller10,000 users16 user groups PC connection using serial (RS232
When Performance Counts39Features single door station / expander max of 14 door stations to each ACTpro 2000/3000 programmable inputs and output
When Performance Counts40Features two door station / expander controls 2 doorsbuilt-in 3 amp monitored PSUbattery deep-discharge protection
When Performance Counts41Features ACT Notifier: SMS / e-mail event alerts (from 2.6) ACTWeb browser based interface for managing users and repor
When Performance Counts42Software (contd.)Featuresadditional operator work stationProduct Code ACTWin pro W/SACTWin pro WorkstationFeaturesallows
When Performance Counts43ACT LanACT Single Channel InterfaceACT 4 Channel InterfaceNetwork & Communication DevicesFeatures4 channel RS232 to RS485
When Performance CountsvIndexProduct Name Description PageCards and Fobs AccessoriesLanyard, Clips,
When Performance Counts44Operating Voltage 12 Volts DC Current Consumption 40 / 150 mAOutput Current Sink 100 mAOperating Temperature -10 to + 5
When Performance Counts45Door Stations ACTpro 100 ACTpro 101 ACTpro 200Product Specification (contd.) Operating Voltage12 Volts DC 12 Volts DC 230 V
When Performance Counts46ACTpro 3000 Door Controller with 2 access points on board, plus additional access point using the ACTpro 100 Door StationACTp
When Performance Counts47From To Network Type Cable Type* CommentsACTpro Controller ACTpro Door stations (ACTpro 100 / ACTpro 200)RS485 Screen twisted
When Performance Counts48From To Network Type Cable Type** CommentsACTpro Controller ACTpro Door stations (ACTpro 100 / 200)RS485 Screen twisted pair(
When Performance Counts49ACTpro 3000 Door Controller, each with a max of 16 doors, connected via Ethernet (TCP / IP) to a PC running the ACTWin softwa
When Performance Counts50ACT 433 Long Range Receiver & Transmitters with pro range of Door Controllers, Door Stations and Readers
When Performance Counts51ACTpro-X Readers May be installed in exposed outdoor conditions (IP67) May be up to 100m when powered from +12V DC May
When Performance Counts52ACTpro IOMFor indoor use only The ACTpro IOM connects to the ACTpro 2000 and 3000 controller on the doors network The
When Performance Counts53Please use these product feature comparison charts to help you choose the device which most suits your needs. ACTpro 1000 ACT
When Performance CountsviIndexProduct Name Description PageAudio Video over IP Door EntryACTentry V-IP Kitaudio video over IP door entry kit including
When Performance Counts54ACTpro-X 1030ACTpro-X 1030PMACTpro-X 1040ACTpro-X 1050ACTpro-X 1060Descriptionslimline multi-format prox multi-format proxmul
When Performance Counts55ACTpro mifare 1040 ACTpro mifare 1050DescriptionContactless smartcard reader Contactless smartcard & pin reader Mountings
When Performance Counts56ACTentry V-IP Door Entry PanelFeaturesEach kit comprises of:ACTentry V-IP door entry panelACTentry V-IP control unitACT
When Performance Counts57Features unlimited users auto video pop-up or discrete mode video bandwidth can be set according to network constrai
When Performance Counts58Features panel mount multi-format proximity readerindoor/outdoor (IP67)Product Code ACTpro-X 1030PMACTpro-X 1030PM Rea
When Performance Counts59Featuresaudio door entry and access control connect up to 4 Door Intercom Handsetsincorrect code lockout10 user code
When Performance Counts60Features1amp, 12 Volt DC power supply unitProduct Code ACTentry 1A Power Supply ACTentry A10 Door Intercom HandsetFeatu
When Performance Counts61ACTentry A10 Audio Door Entry SystemNumber of Users 10 PIN codes Operating Voltage 12 Volts AC or DCCurrent Consumption 3
When Performance Counts62Product SchematicsACTentry V-IP audio video over TCP / IP with multiple usersACTentry A10 audio door entry with up to 4 hands
When Performance Counts63Installation NotesACTentry V-IP Door Entry Panel Mount on a wall near the entrance point and in a sheltered location Sin
When Performance Counts1Product Code ACT 5(includes digital keypad, flush mount plate, surface mount collar, 1 varistor & manual)ACT 5 Digital Ke
When Performance Counts64
Adding value to ACT products the ACT Customer Services department provides a variety of support structures for all clientsCustomer Services
When Performance Counts66TrainingTechnical SupportCustomer ServicesCertified training is an important element of the security industry and ACT has deve
When Performance Counts67Customer Services (contd.) Development & Systems IntegrationOn Site SupportConsultation ServicesACT offers a one stop to
When Performance Counts68
Appendix
When Performance Counts70Glossary of Terms for Access ControlAccessAction of entry into or exit from a security controlled area.Access AuthorisationP
When Performance Counts71Apas open(ed)An apas is open(ed) when the access point affords free passageApas violationUnauthorised operation of an access
When Performance Counts72Fault conditionAny condition which leads to the interruption or degradation of the access control system’s functionality.Guar
When Performance Counts73Real time downloadInformation which can be downloaded in real time from the PC to the controller such as the change in a user
When Performance Counts 2Features pin & proximity digital keypad50 user codes & 50 cards / fobspush to exit inputincorrect code locko
When Performance Counts74Token holderAn individual who has been issued and holds an access control token.Token NumberCoded number stored in the access
When Performance Counts3Features Stainless steel flush mount kit for the ACT 10 digital keypadProduct Code ACT 10FKFeatures Stainless steel weather
Commentaires sur ces manuels